In 1997, a paper at the BevTech meeting reported that tasters could pick out carbonyl sulfide in carbonated water when the CO₂ carried as little as 0.22 ppm of it. The industry specification at the time allowed 0.5 ppm. Several large beverage recalls had already been traced to carbonyl sulfide contamination.
The chair of the International Society of Beverage Technologists CO₂ subcommittee wrote in 2000 that the old specifications had not been tight enough to protect sensory quality. Today the ISBT guideline holds all sulfur compounds in beverage grade CO₂, other than sulfur dioxide, to a combined 0.1 ppm by volume. That ceiling sits below half of what the 1997 tasters could detect.
Odorless in the Tank, Sulfur in the Glass
Carbonyl sulfide, written COS, is one carbon, one oxygen and one sulfur atom. At trace levels in a gas stream it has no smell, so a load can pass a sniff at the receiving dock and still carry it.
In water, COS hydrolyzes into CO₂ and hydrogen sulfide. A carbonated drink is water holding dissolved CO₂, which gives the reaction everything it needs. Some of the conversion can happen after filling, inside a sealed package, where no one is measuring.
Hydrogen sulfide is the rotten egg note, and people smell it at around 10 parts per billion. The consumer finds the defect that the gas itself hid.
Why the Limit Is Written as a Total
The ISBT sulfur line counts every sulfur-containing impurity except sulfur dioxide, measured as sulfur, against one 0.1 ppm budget. Hydrogen sulfide, carbonyl sulfide, mercaptans and dimethyl sulfide all draw from the same allowance. Sulfur dioxide has its own separate limit of 1 ppm.
That structure matters for testing. A hydrogen sulfide reading of zero says nothing about carbonyl sulfide. A load can show no hydrogen sulfide and still be over the total sulfur limit. The ISBT guideline lists sulfur analyzers for total sulfur among its test methods.
The Source Decides Which Sulfur Shows Up
ISBT states that the impurities in carbon dioxide are related to its source and sometimes to its purification process. Commercial CO₂ comes from chemical plants, lime kilns, combustion, fermentation, natural wells and, more recently, biogas upgrading. Each one carries a different set of trace compounds, and the ISBT guideline includes a table of potential impurities by source type.
European industrial gas guidance, as summarized by the Brewers Association, requires a formal food safety assessment at every CO₂ plant that covers the raw gas process and the feedstock. The same summary tells producers to test feed gas sources routinely for compositional changes. The sulfur risk is a property of where the gas came from, and the plant has to know it before it can control it.
Biogas is the clearest example. Published biogas research reports carbonyl sulfide, dimethyl sulfide and methyl mercaptan in raw biogas, often at a few ppm each, alongside hydrogen sulfide. One comparison across biogas sources found average hydrogen sulfide of 181 ppm at wastewater plants and 901 ppm at landfills. By our arithmetic, 901 ppm is about 9,000 times the 0.1 ppm total sulfur ceiling, and a single organic sulfur compound at 3 ppm is 30 times it.
RNG plants typically remove most of the hydrogen sulfide before or during upgrading, since pipeline gas has its own sulfur limit. The question for a CO₂ buyer is what is left in the CO₂ stream after that, and organic sulfur compounds are the ones a hydrogen sulfide system is least built to catch.
Carbon Beds Catch Hydrogen Sulfide First
The workhorse for biogas sulfur cleanup is an adsorbent bed, often activated carbon, sized and monitored for hydrogen sulfide. Research on biogas treatment has found that carbonyl sulfide, carbon disulfide and dimethyl sulfide break through carbon filters long before hydrogen sulfide shows up at the outlet.
So the bed can look healthy on the compound the operator watches while it passes the ones the beverage spec also counts. An outlet analyzer that reads only hydrogen sulfide is watching the last sulfur compound to break through.
Liquefaction Keeps the Sulfur
Cryogenic purification separates compounds by volatility. Methane, nitrogen and oxygen are far more volatile than CO₂, so they leave with the vent gas when the CO₂ condenses. Hydrogen sulfide and carbonyl sulfide are less volatile than CO₂. They stay in the liquid.
That is why the cold step cannot be the sulfur step. Sulfur compounds have to come out in the warm stages upstream, through adsorbent beds and polishing stages built for trace sulfur, before the gas reaches the cold box. Whatever sulfur gets past those stages ends up in the liquid product and travels with it to the customer.
For CO₂ captured from RNG upgrading, the stream CleanCycleCarbon works with, beverage grade at 99.9 percent is the spec we certify to. The purity number gets the attention. On a biogas source, the total sulfur line is where the feedstock shows up.
What This Means for a CO₂ Buyer
Read the sulfur line on the certificate of analysis before the purity line. Check that it reports total sulfur from an analyzer that sees organic sulfur compounds, and not hydrogen sulfide alone.
Ask the supplier which sulfur compounds their source is known to carry. The answer belongs in their food safety assessment, and a supplier who has done that work will have it. Ask again when the source changes. The Brewers Association notes that a shortage in one industry can bring new feed gas sources into the market, and a new source brings its own trace compounds with it.
Carbonyl sulfide is the reason the sulfur limit in beverage grade CO₂ is written as a total. A certificate that reports hydrogen sulfide alone describes the sulfur compound that was easiest to catch.



