Under the decay model EPA uses for landfill gas, a landfill in a wet climate that closes this year will produce about half as much gas ten years from now. The same landfill in a dry climate keeps about 82 percent. Every ton of CO₂ a capture plant at that site will ever see sits somewhere between those two curves.
The model is EPA's Landfill Gas Emissions Model, LandGEM. It treats methane generation as peaking shortly after waste is placed and then falling exponentially as bacteria consume the organic material. A single constant, k, sets the pace. EPA's landfill gas project handbook illustrates the range with 0.02 per year for arid conditions and 0.065 per year for wet ones. The percentages and tonnages below are our own arithmetic on those published values.
A Landfill Draws Down a Fixed Stockpile
An earlier post here argued that the first number on a CO₂ source is tons per day. For a landfill, that number comes with a date attached. EPA puts landfill gas at roughly 45 to 50 percent CO₂, so the vent stream at a landfill RNG plant is large and concentrated. It is also drawn from a stockpile that stopped growing the day the gate closed.
Dairy digesters and wastewater plants behave differently. A digester makes gas from what was loaded into it this week, manure from the herd or solids pulled from the treatment plant's flow. Hold the inputs steady and the output holds steady. A closed landfill has no inputs. Its gas comes from waste already in the ground, and each year there is less of it left to decay.
What the Curve Does to a Capture Plant
Take a landfill source producing 40 tons of CO₂ a day in the year it closes. That fills two of the roughly 20-ton trailers that carry bulk liquid CO₂. Run the model forward at three rates.
- Wet case, k = 0.065. Output drops to about 21 tons a day by year 10 and 11 by year 20, so the source is down to one trailer a day in under 11 years.
- Middle case, k = 0.04. Roughly 27 by year 10 and 18 by year 20.
- Arid case, k = 0.02. Roughly 33 by year 10 and 27 by year 20.
Over a 15-year operating life, the wet site yields about 64 percent of the tons a steady 40-ton-a-day source would. The middle case yields about 75 percent and the arid case about 86 percent. A plant sized to closure-year flow and planned around flat production runs below nameplate from its second year, and the shortfall grows every year after.
Gas collection pushes partly the other way. EPA notes that collection efficiency usually rises after closure, once disposal no longer interferes with the wellfield and a final cover is in place. Reported efficiencies at landfills with comprehensive collection systems run 50 to 95 percent, with 75 percent the figure most often assumed. A site that collected poorly while open can recover a larger share of a shrinking total for a few years. That gain has a ceiling. The decay keeps going.
Open Landfills Run the Other Direction
A landfill still accepting waste sits on the rising side of the same curve. New waste adds generation faster than old waste loses it, and output climbs until filling stops. EPA's initial screening criteria for a landfill gas project include whether the site is open or recently closed and whether it receives at least 25 inches of precipitation a year. Wet sites make gas fastest, which also means they lose it fastest once the gate closes.
That makes current flow the least informative number about a landfill source. The more useful ones are the years of permitted capacity left, the k value in the operator's own gas model, and whether that model has been checked against metered collection. EPA points out that a site with a collection system in place can calibrate modeled recovery against the gas it actually collects. That step turns the curve from a default assumption into a measurement.
The Spec Holds While the Flow Drops
The beverage grade bar does not move as the volume falls. Beverage grade at 99.9 percent is the spec we certify to, with benzene held under 20 parts per billion and moisture at 20 ppm. A purification train on a wet landfill has to hit those numbers at 40 tons a day in its first year and at 21 in its tenth. Equipment for that site should be judged on how it runs at half its design flow, because that is where it will spend its second decade.
What This Means for a Project
For a landfill operator weighing CO₂ capture, the decay curve is the business plan. The closure date and the k value set how many tons a plant will produce over its life, and both belong in the first conversation next to today's flow meter reading.
For a CO₂ buyer looking at a landfill-based supplier, the same curve shows how long that source can carry a contract at today's volume. A dairy or wastewater source makes a different kind of promise. Its output follows the herd or the sewer flow, and either can change, but nothing in its chemistry is counting down.
A closed landfill is a CO₂ source with an end date built into its chemistry, and a capture plant there has to be sized to the whole curve. Today's flow is only its first point.